鲁芯仪器有限公司欢迎您!                                                              加入收藏 | 设为首页
TAS7000
品牌:爱德万
型号:TAS7000
现货:
基本配置价格(US$):

3D Imaging Analysis System

MODEL IMAGE

TAS7000 3D Imaging Analysis System

The TAS7000(*1) 3D(*2) imaging analysis system exploits the unique properties of terahertz waves(*3).The TAS7000 enables 3D non-destructive analysis of the internal structure and chemical composition of the target object; the results are shown on a 3D display. In addition, this system enables measurement of spectral characteristics and 2D(*4) mapping.
Advantest has developed an unprecedented solution for 3D analysis of industrial materials such as plastics and ceramics, as well as pharmaceutical products.

*1: TAS7000 = This system was developed by Advantest in collaboration with Prof. Dr. Kodo Kawase of Nagoya University.

*2: 3D = Three-dimensional

*3: Terahertz waves = Region of electromagnetic spectrum between hundred gigahertz to tens of terahertz.

*4: 2D = Two-dimensional

Features

  • A global first: non-destructive 2D and 3D analysis utilizing Terahertz wave
    The TAS7000 enables non-destructive, 2D and 3D analysis of the internal composition and structure of measurement targets, utilizing computed tomography (CT) and exploiting the unique properties of terahertz waves.
    The TAS7000 enables not only analysis of the structural homogeneity of an internal substance, but also identification of constituents and quantitative distribution measurement.
    Moreover, in contrast with other regions of the electromagnetic spectrum, terahertz waves can penetrate various types of materials with moderate transmittance, allowing for analysis.
  • High-speed measurement utilizes Advantest's terahertz optical sampling technology
    The TAS7000 relies on Advantest's newly developed, ultra-short pulse femtosecond optical fiber laser technology for terahertz wave generation and detection, and utilizes the company's original terahertz wave high-speed optical sampling technique. Thus, it delivers measurement throughput approximately 1000 times greater than the previous system.
  • Broadband terahertz wave spectroscopic analysis up to 3THz
    The TAS7000 enables broadband, high-resolution spectroscopic analysis up to a maximum analytical frequency of 3THz. The system is ideally suited for acquiring fingerprint spectra of a comprehensive range of chemical, industrial, and biological materials. For high precision, the system has the option to remove water vapor from the sample chamber by flowing dry air during the measurement.

img_tas7000_0002_en

Specifications

ApplicationsNon-destructive analysis, 3D constituent density distribution analysis, 3D spectroscopic measurement
Analytical functions2D / 3D computed tomography (CT) density distribution analysis
Terahertz spectroscopic transmission analysis:
  • 2D / 3D CT spectroscopic measurement mode
  • 2D spectroscopic measurement mode (mapping measurement)
  • Spectroscopic measurement mode
Analytical frequency range (?1)High dynamic range module : 0.02THz to 0.6THz Broadband module (?2) : 0.05THz to 3THz
Dynamic range (?1)High dynamic range module : ?60dB (at peak, 3min.)
Broadband module : ?50dB (at peak, 15min.)
Spatial resolution of CT measurement function (?1)?3mm (using wire phantom; modulation transfer function (MTF), 10%)
ThroughputMaximum waveform acquisition speed : 250Hz
?(Spectroscopic measurement mode)
Acquisition time for CT cross section : ?15min.
?(Measurement of 1 CT cross section is divided into 64×64)
Maximum sample size and weight??310mm (12.2inch) × 310mm (12.2inch) (H)
?20kg
Operating environmentTemperature : +10°C to +30°C Relative humidity : ?80% (non-condensing)
Power requirementsAC100V (100-120) / 200V (220-240), 850VA, 50/60Hz
DimensionsSize : 1500mm (W) × 1570mm (d) × 1600mm (H)
Mass : 400kg or less (?3)

Applications: Ceramic Filter Analysis

Non-Destructive Analysis of Ceramic Filters for Reduction of Diesel Engine Emissions

Novel method for non-destructive analysis of ceramic filters

The DPF(?1) is a key component of the after-treatment system that reduces emissions from diesel engine exhaust gas. Analyzing accumulated PM(?2) such as soot and ash in a DPF is critical for optimizing the after-treatment system.

The TAS7000 enables non-destructive analysis of the 3D-PM(?3) distribution in a DPF, as well as soot and ash analyses.

 

?1: DPF = Diesel Particulate Filter

?2: PM = Particulate Matter

?3: 3D = Three-dimensional

img_tas7000_0004_enimg_tas7000_0003

DPF Analysis with the TAS7000

img_tas7000_0006_en

Measurement principle

img_tas7000_0007

Sample DPF

When a DPF sample is placed on the CT test bench, it is scanned with broadband terahertz radiation. By analyzing the spectral characteristics of the radiation transmitted through the sample, the system can display a data-rich graphics of the internal structure and quantitative distribution (g/L) of PM within the sample.

img_tas7000_0005_en

img_tas7000_0009_enimg_tas7000_0008_en

3D-PM quantitative
distribution analysis
of sample

2D-PM quantitative distribution analysis of sample

Advantages of the TAS7000 for DPF Analysis

  • Optimizing product quality using 3D quantitative distribution analysis
    The TAS7000 enables PM quantitative distribution (g/L) analysis in arbitrary areas within DPF samples, allowing developers to obtain data to visualize the thickness of soot and ash layers in detail, and to assess any changes in the internal structure of the filter. This data can facilitate the design of optimal after-treatment systems.
  • Improving R&D efficiency
    By making it possible for the first time to analyze filter samples without physically dissecting them, development time can be sharply reduced. Additionally, repeated analyses of the same sample are possible, allowing for confirmation of results and monitoring changes in follow-up investigations.
  • Ease of operation
    No complicated setup is necessary. Samples are simply placed on the CT test bench.













友情链接: 同惠   eec   安捷伦官方网站   普源山东代理   艾德克斯   福禄克   rigol  